This Zenith Breakaway Gas Cylinder fits ONLY the Zenith 230 Hylo Table or Zenith 60 Stationary breakeaway. The installation of the Zenith Breakaway Gas Cylinder is a medium to hard replacement.
Breakaway Adjustment for Raising By Itself
1. Extend Breakaway Chest all the way up 2. Loosen Jam Nut 3. Turn Shaft Counter clockwise 1/4 Turn 4. Check for Lock If still slipping turn another 1/4 Round till it doesn't slip, but still locks and unlocks. 5. Tighten Lock Nut back down
Breakaway Adjustment for Not Releasing
1. Loosen Jam Nut 2. Turn Shaft Clockwise 1/4 Turn 3. Check for Lock / Unlock . 4.If not unlocking turn another 1/4 Round till it still locks and unlocks , but doesn't slip. 5. Tighten Lock Nut back down
Warranty Information
This New Zenith 230 Breakaway Gas Cylinder is 100% guaranteed to be free of defects for one year from date of purchase.